Useful formulas

Useful formulas

How to calculate the forward speed

Speed is a basic datum to calculate the sprayed volume (liters/hectars or GPA).
When it’s not possible to have a speedometer (and when you want to check its precision), you can do the following:

  • Fill half the tank
  • Measure 100 mt on the field
  • Ride the a.m. distance using gear position and RPM, that you require for the spraying treatment. Record the time it takes you.
  • Repeat the previous point at least 5 times and calculate the average time it took you to ride 100 mt
  • Apply the following formula:

V = Speed (km/h)
s = Distance (mt)
t = Time (seconds)

or

S = Speed (MPH)
d = Distance (ft)
t = Time (seconds)

How to calculate delivery and sprayed volume

Before spraying you need to choose the correct nozzle, according to volume and speed. You can do this calculation with the help of several nozzle delivery charts, but if you want to know the exact delivery of the nozzle you are using, you can do the following:

If these nozzles are fitted to a crop spraying boom, the formula for calculating the sprayed volume is as follows:

When an orchard sprayer is used, calculate the sprayed volume as follows:

How to calculate the required pressure

When the charts don’t report the pressure value, which allows the nozzles to supply the required delivery, you can use the following formula to calculate it:

P1 = required pressure
P2 = pressure on the chart
Q1 = required delivery
q2 = delivery on the chart

Use of no-water based solutions

The reported values have been calculated using water. In case of liquids with a different specific weight (density), if you want to know the real delivery, you have to multiply the values on the charts with a conversion factor, as follows:

Obviously, the more you have density, the more you need pressure to reach the required delivery.

Pressure drop

This is the pressure difference between the inlet and the outlet of a hydraulic plant. Beside of the pipe lenght, this drop is due to branches lines, curves, filters, valves, sections variations etc.
In our catalogue we report the values indicated on the technical charts of our products.

Filtering elements size

The filter efficacy depends on the positioning of the correct net size on the different points of hydraulic system. On the chart you can find the minimum required net size:

In this way you have:

  • correct filtration
  • low pressure drop
  • low maintenance = low costs

Delivery

Volume

Pressure

Delivery

Volume

Pressure